← St Leonards Forest Edge Drive

Spill evidence · River Hub

St Leonards Forest Edge Drive

Pumping station overflow · WXW01043 · feeds FERNDOWN / VERWOOD / WEST MOORS / ST IVES STW
Wet weather

The discharge

Spill day
Tuesday, 2 January 2024
Started
2 Jan 2024, 10:52
Ended
2 Jan 2024, 14:58
Duration
4 hours 6 minutes
Receiving water
Crane (Dorset)
Parish
St. Leonards and St. Ives

Rainfall evidence

Daily rainfall at the matched gauge (Holdenhurst) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
DateRainfall
02/01/2024 (spill day)5.98 mmrain
01/01/202418.81 mmrain
31/12/20231.1 mmrain
30/12/20238.89 mmrain
29/12/20231.3 mmrain

River flow that day: 41.033 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 9.8 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Not Applicable
Ahead of the works
No — the works was also overflowing that day.
EA annual return (2024)
12 counted spills · 66 h total
Monitor uptime (2024)
100% operational
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet WXW01043). Rainfall: EA Hydrology gauge ea79c66d-88d9-409c-b57f-78a40c9ff45e. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Dorset Stour Data.
Spill evidence — St Leonards Forest Edge Drive — River Dorset Stour Data