← Webber St, Falmouth

Spill evidence · River Hub

Webber St, Falmouth

Combined sewer overflow · SBB01326 · feeds FALMOUTH STW
Wet weather

The discharge

Spill day
Monday, 7 October 2024
Started
7 Oct 2024, 16:00
Ended
7 Oct 2024, 16:37
Duration
37 minutes
Receiving water
Kennal
Parish
Falmouth

Rainfall evidence

Daily rainfall at the matched gauge (Penryn) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
DateRainfall
07/10/2024 (spill day)16.997 mmrain
06/10/202419.203 mmrain
05/10/202414.997 mmrain
04/10/20240 mmdry
03/10/20240 mmdry

River flow that day: 6.485 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 3.2 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Fal Estuary
Ahead of the works
Yes — the treatment works' own overflow stayed shut that day, so capacity was available. Avoidable.
EA annual return (2024)
67 counted spills · 44 h total
Monitor uptime (2024)
100% operational
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB01326). Rainfall: EA Hydrology gauge a085d57a-b72f-4ddc-ac54-e139195cd693. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Fal Data.