← St Columb Rd

Spill evidence · River Hub

St Columb Rd

Combined sewer overflow · SBB00998 · feeds ST COLUMB STW
Wet weather

The discharge

Spill day
Friday, 12 December 2025
Started
12 Dec 2025, 00:42
Ended
12 Dec 2025, 01:06
Duration
24 minutes
Receiving water
Gannel (Upper)
Parish
St. Enoder

Rainfall evidence

Daily rainfall at the matched gauge (St Dennis) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
DateRainfall
12/12/2025 (spill day)0.1 mmdry
11/12/202514.604 mmrain
10/12/20250.101 mmdry
09/12/20256.101 mmrain
08/12/202530.503 mmrain

River flow that day: 18.948 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 3.6 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Not Applicable
Ahead of the works
No — the works was also overflowing that day.
EA annual return (2025)
61 counted spills · 30 h total
Monitor uptime (2025)
100% operational
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB00998). Rainfall: EA Hydrology gauge 03fd9d1b-c6db-424c-a7e6-6800134b416c. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by Gannel & Menalhyl Data.