← Brixton STW

Spill evidence · River Yealm Water Quality Group

Brixton STW

Storm overflow at the works · SBB00162 · feeds BRIXTON_STW_BRIXTON
Dry spill

Evidence strength

Medium confidence
  • ✓ Dry on the EA 1-day window
  • ✓ Rain gauge close (≤5 km)
  • ✓ Monitor 100% operational that year
  • ⚠ Short discharge (<1 h) — weaker signal

The discharge

Spill day
Saturday, 6 January 2024
Started
6 Jan 2024, 19:00
Ended
6 Jan 2024, 19:17
Duration
17 minutes 9 seconds
Receiving water
Silverbridge Lake
Parish
Brixton

Rainfall evidence

Daily rainfall at the matched gauge (Plympton) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Dry spill3-day window: Wet weather4-day window: Wet weather
DateRainfall
06/01/2024 (spill day)0 mmdry
05/01/20240.2 mmdry
04/01/202414.3 mmrain
03/01/20243.1 mmrain
02/01/20243.9 mmrain

River flow that day: 19.841 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 4.9 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Yealm
EA annual return (2024)
60 counted spills · 399 h total
Monitor uptime (2024)
100% operational
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB00162). Rainfall: EA Hydrology gauge b779beab-751f-439d-bd30-0f79b866a399. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Yealm Data.