EA sampling point

Hill Deverill Watercress Beds

Sampled by the Environment Agency on 1 visit in 2026.

Phosphate

2026: avg 0.085 · max 0.085 mg/l
00.050.10.150.22026-04-09: 0.085 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2026: avg 0.015 · max 0.015 mg/l
00.20.40.62026-04-09: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2026: avg 83 · min 83 % saturation
60801001202026-04-09: 83.1 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

10.9–10.9 °C

Warm water holds less oxygen. There is no river standard for temperature here.

051015202026-04-09: 10.9 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Conductivity at 25 C (MICROSIEMENS PER CENTIMETRE)

EA sampling point SW-5023GW01 · Wylye (Headwaters) · 563 readings of 133 tests since 2021.

DateResultUnitSample
2026-04-09 09:37577MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-12-17 10:48569MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-05-21 12:01585MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-12-04 12:21525MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-04-02 11:51513MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-12-06 14:35560MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-12-01 13:50566MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-04-04 11:29569MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2021-12-09 12:23587MICROSIEMENS PER CENTIMETREGROUNDWATER - PURGED/PUMPED/REFILLED · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the Bristol Avon Rural.