← Rewe STW

Spill evidence · River Hub

Rewe STW

Storm overflow at the works · SBB01024 · feeds REWE_STW_REWE
Dry spill

Evidence strength

Low confidence
  • ✓ Dry on the EA 1-day window
  • ✓ Rain gauge close (≤5 km)
  • ⚠ Short discharge (<1 h) — weaker signal

The discharge

Spill day
Saturday, 28 March 2026
Started
28 Mar 2026, 11:21
Ended
28 Mar 2026, 11:50
Duration
29 minutes 10 seconds
Receiving water
Lower Culm
Parish
Stoke Canon

Rainfall evidence

Daily rainfall at the matched gauge (Killerton Beare Farm) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Dry spill3-day window: Wet weather4-day window: Wet weather
DateRainfall
28/03/2026 (spill day)0 mmdry
27/03/20260 mmdry
26/03/20260.3 mmrain
25/03/20260 mmdry
24/03/20261.9 mmrain

River flow that day: 3.221 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 4.8 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Not Applicable
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB01024). Rainfall: EA Hydrology gauge 48e0df21-a0d4-46f0-9234-ee9306935416. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by Clyst & Culm Data.