EA sampling point
Tresavean Adit
Sampled by the Environment Agency on 4 visits in 2025.
Ammonia
2025: avg 0.015 · max 0.015 mg/lHigh ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1
Dissolved oxygen
2025: avg 84 · min 82 % saturationHigh ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50
Water temperature
13.2–14.1 °CWarm water holds less oxygen. There is no river standard for temperature here.
Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.
Every reading: Alkalinity to pH 4.5 as CaCO3 (MILLIGRAM PER LITRE)
EA sampling point SW-81950891 · Hicks Mill Stream · 1,662 readings of 53 tests since 2021.
| Date | Result | Unit | Sample |
|---|---|---|---|
| 2025-04-24 12:08 | 11 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2025-03-18 11:39 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2025-02-18 12:01 | 10 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2025-01-29 12:46 | 8 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-12-11 16:01 | 8 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-11-20 14:04 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-10-15 14:11 | 8 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-09-27 12:09 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-08-14 14:17 | 8 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-07-22 13:51 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-06-27 15:48 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-05-09 13:40 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2024-04-24 13:44 | 5 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2023-03-22 11:40 | 11 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2023-02-16 11:36 | 9 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2023-01-25 12:26 | 9 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-12-07 14:56 | 12 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-11-09 12:53 | 13 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-09-01 13:13 | 9 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-07-27 11:24 | 10 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-05-24 14:14 | 10 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-03-21 15:53 | 10 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-02-08 14:59 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2022-01-27 15:13 | 9 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2021-11-25 14:07 | 9 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2021-10-21 16:10 | 10 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2021-09-22 14:30 | 9 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (NATIONAL AGENCY POLICY) |
| 2021-07-21 13:58 | 7 | MILLIGRAM PER LITRE | RIVER / RUNNING SURFACE WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS) |
| 2021-05-24 11:02 | 8 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (UK GOVT POLICY - NOT GQA OR RE) |
| 2021-04-07 14:16 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (UK GOVT POLICY - NOT GQA OR RE) |
| 2021-03-08 15:38 | 7 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (UK GOVT POLICY - NOT GQA OR RE) |
| 2021-02-23 13:38 | 11 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (UK GOVT POLICY - NOT GQA OR RE) |
| 2021-01-20 14:07 | 9 | MILLIGRAM PER LITRE | MINEWATER (FLOWING/PUMPED) · MONITORING (UK GOVT POLICY - NOT GQA OR RE) |
Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the River Fal.