← Warminster Storm Tank

Spill evidence · River Hub

Warminster Storm Tank

Storm overflow at the works · WXW01192 · feeds WARMINSTER STW
Wet weather

The discharge

Spill day
Wednesday, 28 January 2026
Started
28 Jan 2026, 08:56
Ended
28 Jan 2026, 14:46
Duration
5 hours 50 minutes
Receiving water
Wylye (Headwaters)
Parish
Warminster

Rainfall evidence

Daily rainfall at the matched gauge (Westbury Dilton Court) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
DateRainfall
28/01/2026 (spill day)0.2 mmdry
27/01/20264 mmrain
26/01/202618.8 mmrain
25/01/20260.6 mmrain
24/01/202614 mmrain

River flow that day: 29.046 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 5.4 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Not Applicable
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet WXW01192). Rainfall: EA Hydrology gauge eb5738b8-6614-41e7-888f-6909962888d1. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Hampshire Avon Data.