EA sampling point

Lydney Park Estate Spring Gwqn

Sampled by the Environment Agency on 2 visits in 2026.

Phosphate

2026: avg 0.014 · max 0.023 mg/l
00.050.10.150.22026-03-27: below 0.01 mg/l2026-09-10: 0.023 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2026: avg 0.015 · max 0.015 mg/l
00.20.40.62026-03-27: below 0.03 mg/l2026-09-10: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2026: avg 83 · min 82 % saturation
60801001202026-03-27: 81.8 % saturation2026-09-10: 84.1 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

10.4–12.5 °C

Warm water holds less oxygen. There is no river standard for temperature here.

051015202026-03-27: 10.4 °C2026-09-10: 12.5 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Conductivity at 25 C (MICROSIEMENS PER CENTIMETRE)

EA sampling point MD-00218740 · Warth Bk - source to R Severn Estuary · 872 readings of 133 tests since 2021.

DateResultUnitSample
2026-09-10 12:12620MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2026-03-27 10:16679MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-09-18 10:21627MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-06-12 12:25644MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2025-03-18 11:21630MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-07-01 10:35636MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-05-07 12:39641MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2024-03-04 11:23642MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-09-12 11:11630MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-07-25 12:06624MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2023-03-09 13:44621MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-09-06 10:22631MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-07-13 09:33636MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-05-23 10:59638MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2022-03-07 10:41644MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2021-10-28 11:13644MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)
2021-07-27 11:04646MICROSIEMENS PER CENTIMETREGROUNDWATER · ENVIRONMENTAL MONITORING STATUTORY (EU DIRECTIVES)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the Lower Severn Vale.