EA sampling point

Investigation in Catchment 15b

Sampled by the Environment Agency on 1 visit in 2024.

Ammonia

2024: avg 0.015 · max 0.015 mg/l
00.20.40.62024-08-12: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2024: avg 71 · min 71 % saturation
60801001202024-08-12: 70.8 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

13.4–13.4 °C

Warm water holds less oxygen. There is no river standard for temperature here.

051015202024-08-12: 13.4 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Aluminium (MICROGRAM PER LITRE)

EA sampling point SW-81528801 · 282 readings of 54 tests since 2021.

DateResultUnitSample
2024-08-12 12:00< 20MICROGRAM PER LITREMINEWATER · PLANNED INVESTIGATION (LOCAL MONITORING)
2023-01-18 12:5579MICROGRAM PER LITREMINEWATER · PLANNED INVESTIGATION (LOCAL MONITORING)
2022-11-25 12:2596MICROGRAM PER LITREANY WATER · PLANNED INVESTIGATION (LOCAL MONITORING)
2022-07-29 10:5065MICROGRAM PER LITREANY WATER · PLANNED INVESTIGATION (LOCAL MONITORING)
2022-06-07 12:4664MICROGRAM PER LITREMINEWATER · PLANNED INVESTIGATION (LOCAL MONITORING)
2022-05-19 12:4569MICROGRAM PER LITREANY WATER · STATUTORY FAILURES (FOLLOW UPS AT NON-DESIGNATED POINTS)
2021-11-09 12:5023MICROGRAM PER LITREMINEWATER (FLOWING/PUMPED) · UNPLANNED REACTIVE MONITORING (POLLUTION INCIDENTS)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the Par & St Austell.