Trib of R. Wolf @ Aller Farm

Sampled by the Environment Agency on 12 visits in 2022. Phosphate averages moderate, below the good standard. Ammonia and dissolved oxygen are high. Averages are over 2020–2022.

Phosphate

2022: avg 0.094 · max 0.160 mg/l

Band, 2020–2022 average: 0.094 · Moderate

00.050.10.150.22022-01-12: 0.062 mg/l2022-02-01: 0.061 mg/l2022-03-18: 0.06 mg/l2022-04-01: 0.047 mg/l2022-05-06: 0.062 mg/l2022-06-16: 0.16 mg/l2022-07-01: 0.11 mg/l2022-09-12: 0.14 mg/l2022-10-07: 0.14 mg/l2022-11-09: 0.099 mg/l2022-12-06: 0.088 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2022: avg 0.019 · max 0.054 mg/l

Band, 2020–2022 average: 0.019 · High

00.20.40.62022-01-12: below 0.03 mg/l2022-02-01: below 0.03 mg/l2022-03-18: below 0.03 mg/l2022-04-01: below 0.03 mg/l2022-05-06: below 0.03 mg/l2022-06-16: 0.054 mg/l2022-07-01: below 0.03 mg/l2022-09-12: below 0.03 mg/l2022-10-07: below 0.03 mg/l2022-11-09: below 0.03 mg/l2022-12-06: below 0.03 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2022: avg 98 · min 84 % saturation

Band, 2020–2022 average: 98 · High

60801001202022-01-12: 102.1 % saturation2022-02-01: 98 % saturation2022-03-18: 100.7 % saturation2022-04-01: 100.5 % saturation2022-05-06: 102 % saturation2022-06-16: 83.8 % saturation2022-07-01: 96 % saturation2022-09-12: 96 % saturation2022-10-07: 109.8 % saturation2022-11-09: 99.1 % saturation2022-12-06: 94.4 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

5.3–15.8 °C

Warm water holds less oxygen. There is no river standard for temperature here.

051015202022-01-12: 6.7 °C2022-02-01: 7.9 °C2022-03-18: 11.2 °C2022-04-01: 5.3 °C2022-05-06: 11.2 °C2022-06-16: 13.8 °C2022-07-01: 11.7 °C2022-09-12: 15.8 °C2022-10-07: 13.1 °C2022-11-09: 11.7 °C2022-12-06: 6.6 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: 2-Phenoxypropionic acid :- {PPA} (MICROGRAM PER LITRE)

EA sampling point SW-RSN0755 · Wolf (Otter) · 1,263 readings of 117 tests since 2022.

DateResultUnitSample
2022-12-06 10:49< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-11-09 09:57< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-10-07 14:21< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-09-12 10:32< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-07-01 08:33< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-06-16 11:16< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-05-06 08:58< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-04-01 10:31< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-03-18 13:51< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-02-01 10:08< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2022-01-12 11:13< 0.005MICROGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)