← Langore pumping station, Launceston

Spill evidence · River Hub

Langore pumping station, Launceston

Pumping station overflow · SBB00663 · feeds LAUNCESTON STW
Wet weather

The discharge

Spill day
Tuesday, 2 January 2024
Started
2 Jan 2024, 07:49
Ended
2 Jan 2024, 10:06
Duration
2 hours 17 minutes
Receiving water
Lower River Ottery
Parish
St. Stephens by Launceston Rural

Rainfall evidence

Daily rainfall at the matched gauge (Werrington Park) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.

1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
DateRainfall
02/01/2024 (spill day)11.2 mmrain
01/01/202430 mmrain
31/12/20239.8 mmrain
30/12/202320.2 mmrain
29/12/20231.2 mmrain

River flow that day: 41.033 m³/s. Verify at the EA rainfall station.

Gauge proximity

Outlet (red) vs matched rain gauge (blue), 3.7 km apart. Closer means the rainfall reading is more representative of the overflow.

Loading map…

Severity & context

Bathing water
Not Applicable
Shellfish water
Not Applicable
Ahead of the works
No — the works was also overflowing that day.
EA annual return (2024)
16 counted spills · 31 h total
Monitor uptime (2024)
100% operational
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB00663). Rainfall: EA Hydrology gauge 68504bb6-817a-4ba1-b6b3-e59a08cac69f. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by Upper Tamar Data.