What the regulator requires
A measure is a specific action the regulator requires the water company to take at a named site — to investigate a problem, keep monitoring it, or physically fix it — each with a completion date. These are the legally binding measures on record for this catchment: what each requires, and what to watch.
These measures are legally binding. Each one is a dated, site-specific requirement the company must deliver.
The Water Industry National Environment Programme is how the Environment Agency turns statutory duties into named obligations at named sites, with a completion date attached. Where a measure requires a physical upgrade, the Agency writes the result into the site's environmental permit — and from that point the requirement is criminally enforceable.
The measure itself is public. What is not published is the water company's action to comply with it — its delivery is reported to the regulator and scored, but the underlying work, and whether a measure has actually resolved the problem on the ground, is not on the public record. What to watch is slippage: a measure can be re-dated or re-scoped, and until the permit is varied the obligation has not changed.
What the types mean
A physical upgrade — bigger storage, better treatment, more capacity. This is the only type that actually fixes the problem on the ground.
A study of the cause. It produces a report, not a repair — an investigation must lead to an improvement before anything changes.
Installing or running instruments to measure the problem. Necessary evidence, but on its own it fixes nothing — it too has to be followed by an improvement.
So an overflow whose only measures are investigations or monitoring is being looked at, not yet fixed. On the gaps page, only a measure that is still active counts as action — a measure completed while the overflow is still failing does not.
| Reference | Driver | Type | What it requires | Status | Attached to |
|---|---|---|---|---|---|
| 08SW104311 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) BOYTON STW | Due 2026-27 | Tamar (River Ottery to River Deer) |
| 08SW104942 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) Bridgerule STW | Due 2026-27 | Tamar (Small Brook to River Deer) |
| 08SW104941 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) Bridgerule STW | Due 2026-27 | Tamar (Small Brook to River Deer) |
| 08SW104309 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) EGLOSKERRY STW | Due 2026-27 | Kensey |
| 08SW104317 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) EGLOSKERRY STW | Due 2026-27 | Kensey |
| 08SW104813 · a | U_MON4 | Monitoring | PR24 U_MON4 from U_INV2 investigation (U_MON4c) HALWILL SEWAGE TREATMENT WORKS | Due 2026-27 | Carey |
| 08SW104814 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) HALWILL SEWAGE TREATMENT WORKS | Due 2026-27 | Carey |
| 08SW104784 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) Holsworthy (Derriton) STW | Due 2026-27 | Deer |
| 08SW104783 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) Holsworthy (Derriton) STW | Due 2026-27 | Deer |
| 08SW104758 · a | U_MON4 | Monitoring | Move AMP7 U_MON4 driver output to 2-minute flow monitoring (U_MON4a) LAUNCESTON (ST LEONARDS) STW | Due 2026-27 | Kensey |
| 08SW104759 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) LAUNCESTON (ST LEONARDS) STW | Due 2026-27 | Kensey |
| 08SW104699 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) NORTH PETHERWIN STW | Due 2026-27 | Bolesbridge Water |
| 08SW104698 · a | U_MON4 | Monitoring | Move AMP7 U_INV2 driver output to 2-minute flow monitoring (U_MON4b) NORTH PETHERWIN STW | Due 2026-27 | Bolesbridge Water |
| 08SW104654 · a | U_MON3 | Monitoring | MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor (U_MON3a) PYWORTHY SEWAGE TREATMENT WORKS | Due 2026-27 | Derril Water |
| 08SW104653 · a | U_MON4 | Monitoring | Move AMP7 U_INV2 driver output to 2-minute flow monitoring (U_MON4b) PYWORTHY SEWAGE TREATMENT WORKS | Due 2026-27 | Derril Water |
| 08SW100019 · d | WFD_INV_WRHMWB | Investigation | Investigation and options appraisal to review impact of reservoir on habitat and flows Upper Tamar Lake | Due 2026-27 | Upper River Tamar |
| 08SW102001 · b | WFD_NDLS_Chem2 | No deterioration | Cypermethrin standstill permit limit DERRITON_STW_HOLSWORTHY | Due 2026-27 | Deer |
| 08SW104999 · as | EnvAct_INV4 | Investigation | Investigation to meet EnvAct INV4 Driver DERRITON STW_SO_HOLSWORTHY | Due 2027-28 | DERRITON STW_SO_HOLSWORTHY |
| 08SW100192 · a | WFD_INV | Investigation | *Holding Line* investigation to inform potential requirements for AMP9 DERRITON STW, SLATE COURT STW, CANAL FARM STW | Due 2027-28 | Deer |
| 08SW104999 · ay | EnvAct_INV4 | Investigation | Investigation to meet EnvAct INV4 Driver EGLOSKERRY SPS_PSCSOEO_LAUNCESTON | Due 2027-28 | EGLOSKERRY SPS_PSCSOEO_LAUNCESTON |
| 08SW104999 · bx | EnvAct_INV4 | Investigation | Investigation to meet EnvAct INV4 Driver LANGORE SPS_PSCSOEO_LAUNCESTON | Due 2027-28 | LANGORE SPS_PSCSOEO_LAUNCESTON |
| 08SW104285 · f | EnvAct_INV4 | Investigation | Investigation to meet EnvAct INV4 Driver NORTH PETHERWIN STW_SO_NORTH PETHERWIN | Due 2027-28 | NORTH PETHERWIN STW_SO_NORTH PETHERWIN |
| 08SW104999 · ic | EnvAct_INV4 | Investigation | Investigation to meet EnvAct INV4 Driver ST LEONARDS STW_SSO_LAUNCESTON | Due 2027-28 | ST LEONARDS STW_SSO_LAUNCESTON |
| 08SW104999 · fh | EnvAct_INV4 | Investigation | Investigation to meet EnvAct INV4 Driver YEOLMBRIDGE SPST_PSCSOEO_YEOLMBRIDGE | Due 2027-28 | YEOLMBRIDGE SPST_PSCSOEO_YEOLMBRIDGE |
| 08SW104999 · fi | EnvAct_INV4 | Investigation | Investigation to meet EnvAct INV4 Driver YEOLMBRIDGE_CSO_YEOLMBRIDGE | Due 2027-28 | YEOLMBRIDGE_CSO_YEOLMBRIDGE |
| 08SW100095 · a | EnvAct_IMP2 | Improvement | Reduction of spills to meet EnvAct_IMP drivers DERRITON STW_SO_HOLSWORTHY | Due 2029-30 | DERRITON STW_SO_HOLSWORTHY |
| 08SW100096 · a | EnvAct_IMP2 | Improvement | Reduction of spills to meet EnvAct_IMP drivers DERRITON STW_SSO_HOLSWORTHY | Due 2029-30 | DERRITON STW_SSO_HOLSWORTHY |
| 08SW101532 · a | WFD_IMPg | Improvement | New or tightened P consent HALWILL_STW_HALWILL | Due 2029-30 | Carey |
| 08SW101059 · a | WFD_IMPg | Improvement | New or tightened P consent PYWORTHY_STW_PYWORTHY | Due 2029-30 | Derril Water |
| 08SW102113 · f | U_IMP1 | Improvement | Improve discharge from agglomeration that has crossed 250 and has envirronmental imapct BOYTON_STW_BOYTON | Due 2030-31 | Tamar (River Ottery to River Deer) |
| 08SW102113 · i | U_IMP1 | Improvement | Improve discharge from agglomeration that has crossed 250 and has envirronmental imapct CANAL FARM_STW_CHILSWORTHY | Due 2030-31 | Deer |
| 08SW102113 · k | U_IMP1 | Improvement | Improve discharge from agglomeration that has crossed 250 and has envirronmental imapct EGLOSKERRY_STW_EGLOSKERRY | Due 2030-31 | Kensey |
| 08SW102148 · a | U_IMP2 | Improvement | Already had P stripping WFD will require Monitoring only ST LEONARDS_STW_LAUNCESTON | Due 2030-31 | Tamar (River Ottery to River Lyd) |
| 08SW102113 · af | U_IMP1 | Improvement | Improve discharge from agglomeration that has crossed 250 and has envirronmental imapct WARBSTOW_STW_WARBSTOW | Due 2030-31 | Canworthy Water |
| 08SW102113 · ai | U_IMP1 | Improvement | Improve discharge from agglomeration that has crossed 250 and has envirronmental imapct WHITSTONE_STW_WHITSTONE | Due 2030-31 | Tamar (Small Brook to River Deer) |
| 08SW102113 · aj | U_IMP1 | Improvement | Improve discharge from agglomeration that has crossed 250 and has envirronmental imapct YEOLMBRIDGE_STW_YEOLMBRIDGE | Due 2030-31 | Lower River Ottery |
36 of 36 measures shown. A measure whose completion date has passed is shown as Complete; the water company's actual delivery against it is reported to the regulator but not published here.
There is no public change log
The live WINEP spreadsheet is internal, and there is no versioned public comparison or published reasons when a measure is re-dated or dropped. The only way to hold slippage to account is to archive every annual release and diff it yourself.
The 2027 pressure point
Most investigations must complete by 30 April 2027 to feed the 2030–35 programme. That date — not 2030 — is the one to hold: an investigation that slips past it cannot shape the next round of funded schemes.