EA sampling point

Bolney Sewer upstream of Brooklands Farm

Sampled by the Environment Agency on 12 visits from 2022 to 2024. Phosphate, ammonia and dissolved oxygen are high. Averages are over 2022–2024.

Phosphate

2022–2024: avg 0.035 · max 0.053 mg/l

Band, 2022–2024 average: 0.035 · High

00.050.10.150.2202320242024-01-03: 0.023 mg/l2024-03-27: 0.013 mg/l2024-04-18: 0.028 mg/l2024-05-10: 0.022 mg/l2024-06-06: 0.048 mg/l2024-07-08: 0.04 mg/l2024-08-07: 0.042 mg/l2024-09-09: 0.053 mg/l2024-10-24: 0.029 mg/l2024-11-05: 0.034 mg/l2024-12-10: 0.049 mg/l
High ≤ 0.036Good ≤ 0.069Moderate ≤ 0.173Poor ≤ 1.003Bad > 1.003

Ammonia

2022–2024: avg 0.041 · max 0.180 mg/l

Band, 2022–2024 average: 0.041 · High

00.20.40.6202320242024-01-03: 0.04 mg/l2024-02-07: 0.07 mg/l2024-03-27: 0.18 mg/l2024-04-18: 0.045 mg/l2024-05-10: below 0.03 mg/l2024-06-06: below 0.03 mg/l2024-07-08: below 0.03 mg/l2024-08-07: below 0.03 mg/l2024-09-09: 0.034 mg/l2024-10-24: below 0.03 mg/l2024-11-05: below 0.03 mg/l2024-12-10: 0.035 mg/l
High ≤ 0.2Good ≤ 0.3Moderate ≤ 0.75Poor ≤ 1.1Bad > 1.1

Dissolved oxygen

2022–2024: avg 91 · min 85 % saturation

Band, 2022–2024 average: 91 · High

6080100120202320242024-01-03: 95.6 % saturation2024-02-07: 93.4 % saturation2024-03-27: 96.5 % saturation2024-04-18: 96.4 % saturation2024-05-10: 88 % saturation2024-06-06: 89.6 % saturation2024-07-08: 84.9 % saturation2024-08-07: 85 % saturation2024-09-09: 84.6 % saturation2024-10-24: 91.2 % saturation2024-11-05: 89.3 % saturation2024-12-10: 95.4 % saturation
High ≥ 80Good ≥ 75Moderate ≥ 64Poor ≥ 50Bad < 50

Water temperature

7.6–15.5 °C

Warm water holds less oxygen. There is no river standard for temperature here.

05101520202320242024-01-03: 9.2 °C2024-02-07: 8.4 °C2024-03-27: 9 °C2024-04-18: 9.5 °C2024-05-10: 13.9 °C2024-06-06: 12.8 °C2024-07-08: 13.8 °C2024-08-07: 15.5 °C2024-09-09: 14.9 °C2024-10-24: 11.2 °C2024-11-05: 11.6 °C2024-12-10: 7.6 °C

Shading shows the Water Framework Directive river standards. Hollow dots are readings below the lab’s detection limit, drawn at the limit; averages count them at half the limit. Bands are indicative: the Environment Agency’s formal classification also uses percentiles and, for phosphate, limits set for each stretch of river.

Every reading: Alkalinity to pH 4.5 as CaCO3 (MILLIGRAM PER LITRE)

EA sampling point SO-RSN2285 · Bolney Sewer · 207 readings of 18 tests since 2024.

DateResultUnitSample
2024-12-10 11:1581MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-11-05 12:4897MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-10-24 13:2387MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-09-09 12:5190MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-08-07 13:10120MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-07-08 12:54110MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-06-06 12:5893MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-05-10 13:4570MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-04-18 11:4776MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-03-27 12:0569MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-02-07 10:1374MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)
2024-01-03 09:4358MILLIGRAM PER LITRERIVER / RUNNING SURFACE WATER · MONITORING (NATIONAL AGENCY POLICY)

Source: Environment Agency Water Quality Archive, Open Government Licence. The regulator’s own monitoring of the Arun & Western Rother.