Who is fixing it

Gaps

A gap is an overflow with a flagged problem and no measure recorded against it — the clearest thing on this site to put to a regulator.

34of 50 overflows

34 overflows have a known problem and no measure recorded against them.

Between them these overflows account for about 18,206 hours of discharge in the last full year and 1,210 dry-weather spills since 2020. A dry-weather spill has no rainfall to excuse it — on any reading of regulation 4, that is a prima facie breach with nothing on record to address it.

Each flagged problem carries a weight that scales with its magnitude; an overflow's severity is the sum of its weights. A gap is a flagged overflow with no measure linked to it. An unlinked overflow is not proof that nothing is being done — it is what the public record shows. Frequency here is measured in discharge events — every discrete discharge over 15 minutes, not the Environment Agency's counted-spills figure. How we weight problems → Two ways to count →

1wt 19
Exton South pumping station, ExmouthPS-CSO/EO
SBB00435 · to Exeter STW
Very long spillsDry spillingSpills before its worksHigh spill frequency
1,736 hours in the last full year
No measure recorded
2wt 15
Rewe STWSSO
SBB01024 · to Rewe STW
High spill frequencyVery long spillsDry spilling
4,622 discharge events since 2020
No measure recorded
3wt 15
Odhams Wharf pumping station, EbfordPS-CSO/EO
SBB00401 · to Exeter STW
Very long spillsDry spillingSpills before its works
1,438 hours in the last full year
No measure recorded
4wt 15
Dulford pumping stationPS-CSO/EO
SBB00379 · to Dulford STW
Very long spillsDry spillingSpills before its works
2,411 hours in the last full year
No measure recorded
5wt 10
Holcombe Rogus STWSSO
SBB00579 · to Holcombe Rogus STW
Very long spillsDry spilling
1,110 hours in the last full year
No measure recorded
6wt 10
Clyst Honiton pumping station, ExeterPS-CSO
SBB00279 · to Exeter STW
Dry spillingSpills before its works
22 dry spills since 2020
No measure recorded
7wt 10
Bradninch STWSSO
SBB01379 · to Bradninch STW
Very long spillsDry spilling
1,549 hours in the last full year
No measure recorded
8wt 10
Stoneyford pumping station, CullomptonPS-CSO/EO
SBB01187 · to Cullompton STW
Very long spillsSpills before its works
931 hours in the last full year
No measure recorded
9wt 9
Holcombe Rogus STWSO
SBB00578 · to Holcombe Rogus STW
High spill frequencyDry spillingFeed unreliable
429 discharge events since 2020
No measure recorded
10wt 9
Talaton pumping stationPS-CSO/EO
SBB01202 · to Talaton STW
Spills before its worksHigh spill frequency
411 times since 2020
No measure recorded
11wt 8
Corner Lane pumping station, HalbertonPS-CSO/EO
SBB00306 · to Halberton STW
Spills before its worksDry spilling
249 times since 2020
No measure recorded
12wt 8
WoodburySSO
SBB01374 · to Exeter STW
Very long spillsDry spilling
1,002 hours in the last full year
No measure recorded
13wt 7
Willand STWSO
SBB01362 · to Willand STW
High spill frequencyDry spilling
409 discharge events since 2020
No measure recorded
14wt 7
Sampford Peverell STWSSO
SBB01048 · to Sampford Peverell STW
Very long spillsDry spilling
545 hours in the last full year
No measure recorded
15wt 7
Halberton STWSSO
SBB01419 · to Halberton STW
Very long spillsDry spilling
822 hours in the last full year
No measure recorded
16wt 5
Uffculme pumping stationPS-CSO/EO
SBB01292 · to Uffculme STW
Spills before its works
285 times since 2020
No measure recorded
17wt 5
Ham Ln, WoodburyCSO
SBB00531 · to Woodbury STW
Spills before its works
240 times since 2020
No measure recorded
18wt 5
Stoke Canon pumping stationPS-CSO/EO
SBB01175 · to Rewe STW
Spills before its works
20 times since 2020
No measure recorded
19wt 5
Duke Street pumping station, CullomptonPS-CSO/EO
SBB00378 · to Cullompton STW
Spills before its works
84 times since 2020
No measure recorded
20wt 5
Dunkeswell pumping stationPS-CSO/EO
SBB00383 · to Dunkeswell STW
Spills before its works
30 times since 2020
No measure recorded
21wt 5
Side pumping station, BroadclystPS-CSO/EO
SBB00163 · to Exeter STW
Spills before its works
26 times since 2020
No measure recorded
22wt 5
Penspool pumping station, PlymtreePS-CSO/EO
SBB00920 · to Plymtree STW
Spills before its works
21 times since 2020
No measure recorded
23wt 5
Langaton Ln, ExeterCSO
SBB00662 · to Exeter STW
Spills before its works
28 times since 2020
No measure recorded
24wt 5
Millmoor, CulmstockCSO
SBB00786 · to Culmstock STW
Spills before its works
22 times since 2020
No measure recorded
25wt 5
Church Road Sso, WhimpleCSO
SBB00263 · to Exeter STW
Spills before its works
16 times since 2020
No measure recorded
26wt 5
Forge Way Car Park, CullomptonCSO
SBB00473 · to Cullompton STW
Spills before its works
17 times since 2020
No measure recorded
27wt 4
Culmstock STWSO
SBB00342 · to Culmstock STW
Very long spills
581 hours in the last full year
No measure recorded
28wt 4
Aylesbeare STWSO
SBB00060 · to Aylesbeare STW
Very long spills
831 hours in the last full year
No measure recorded
29wt 4
Willand STWSSO
SBB01363 · to Willand STW
Very long spills
872 hours in the last full year
No measure recorded
30wt 3
Hemyock pumping stationPS-CSO/EO
SBB00564 · to Hemyock STW
Spills before its works
10 times since 2020
No measure recorded
31wt 3
Station Road pumping station, WillandPS-CSO/EO
SBB01163 · to Willand STW
Spills before its works
4 times since 2020
No measure recorded
32wt 3
Poltimore pumping station, ExeterPS-CSO/EO
SBB00800 · to Exeter STW
Spills before its works
4 times since 2020
No measure recorded
33wt 3
Monkerton pumping station, ExeterPS-CSO/EO
SBB00796 · to Exeter STW
Spills before its works
4 times since 2020
No measure recorded
34wt 2
Middle Mill Ln, CullomptonCSO
SBB00771 · to Cullompton STW
Feed unreliable
no reading for 23h
No measure recorded

What is funded, and where

South West Water reports 291 funded overflow improvements across its region, and Ofwat has secured £24m in section 19 undertakings — including £20m to reduce discharges at specific overflows in sensitive and community areas. Which overflows those schemes cover, and whether any of them address the gaps above, is a fair question to put to the company in writing.