DonateLog in
River Hub
Why it keeps happening

Why it keeps happening

Three things we can measure in the data. None of them proves a cause on its own, but each points at a different kind of infrastructure problem.

Indicator 1
1Dry
overflows spilling with no rain to excuse it

A discharge in dry weather is not an exceptional circumstance, so it is not permitted on any reading of regulation 4.

See the 1 →
Indicator 2
0Overloaded
works whose estimated load sits above their permitted flow

A strong signal, not a finding. We cannot see whether flow is transferred to another works for treatment, and the permitted figure is not always published.

See the 0 →
Indicator 3
43Early
overflows that spilled while their works stayed shut

Rainfall across the catchment does not explain a discharge that an overflow's own treatment works did not share.

See the 43 →

Where the indicators concentrate

OverflowHoursDryWhat it points toVerdict
Budds Farm Havant, - 115936SSO6276Very long spillsNo action
Priors Leaze Lane Nutbourne, - 111267CSO1890Spills before its worksNo action
Gladys Avenue Portsmouth, - 108434CSO990Spills before its worksNo action
Court Lane Cosham, - 115958SSO850Spills before its worksNo action
North End Avenue Portsmouth, - 108773CSO630Spills before its worksNo action
Hoeford Fareham Ceo - 108442610Spills before its worksNo action
Old Portsmouth Road, - 111371CSO460Spills before its worksNo action
Fareham Road Gosport Outside 359, - 108505CSO430Spills before its worksNo action
Pier Road Southsea, - 108469CSO420Spills before its worksNo action
Elmhurst Road Fareham, - 108425CSO362Spills before its worksNo action

Hours are the last full year; dry spills are since 2020. Verdict is whether a measure is linked to the overflow — see the gaps.

What this analysis cannot see

These indicators are measured from spill timing and rainfall alone. They cannot see misconnections, the quality of effluent from a works that is running normally, flow transferred between works for treatment, a company's maintenance history, or the periods when a monitor was offline. Because a quiet monitor records nothing, every count here is a floor, not a total.