What the regulator requires
A measure is a specific action the regulator requires the water company to take at a named site — to investigate a problem, keep monitoring it, or physically fix it — each with a completion date. These are the legally binding measures on record for this catchment: what each requires, and what to watch.
These measures are legally binding. Each one is a dated, site-specific requirement the company must deliver.
The Water Industry National Environment Programme is how the Environment Agency turns statutory duties into named obligations at named sites, with a completion date attached. Where a measure requires a physical upgrade, the Agency writes the result into the site's environmental permit — and from that point the requirement is criminally enforceable.
The measure itself is public. What is not published is the water company's action to comply with it — its delivery is reported to the regulator and scored, but the underlying work, and whether a measure has actually resolved the problem on the ground, is not on the public record. What to watch is slippage: a measure can be re-dated or re-scoped, and until the permit is varied the obligation has not changed.
What the types mean
A physical upgrade — bigger storage, better treatment, more capacity. This is the only type that actually fixes the problem on the ground.
A study of the cause. It produces a report, not a repair — an investigation must lead to an improvement before anything changes.
Installing or running instruments to measure the problem. Necessary evidence, but on its own it fixes nothing — it too has to be followed by an improvement.
So an overflow whose only measures are investigations or monitoring is being looked at, not yet fixed. On the gaps page, only a measure that is still active counts as action — a measure completed while the overflow is still failing does not.
| Reference | Driver | Type | What it requires | Status | Attached to |
|---|---|---|---|---|---|
| 08SO102557 · a | U_MON4 | Monitoring | U_MON4c - PR24 U_MON4 from U_INV2 investigation including civils CHILBOLTON WTW | Due 2026-27 | CHILBOLTON |
| 08SO102718 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor CHILBOLTON WWTW | Due 2026-27 | Test - conf Dever to conf Anton |
| 08SO102415 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring East Grimstead WTW | Due 2026-27 | Dun |
| 08SO102733 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor EAST GRIMSTEAD WWTW | Due 2026-27 | Dun |
| 08SO102755 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor FRITTENDEN WWTW | Due 2026-27 | Test - conf Dever to conf Anton |
| 08SO102418 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring Fullerton WTW | Due 2026-27 | Test - conf Dever to conf Anton |
| 08SO102756 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor FULLERTON WWTW | Due 2026-27 | Test - conf Dever to conf Anton |
| 08SO102492 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring Kings Somborne WTW | Due 2026-27 | Test - conf Anton to conf Dun |
| 08SO102789 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor KINGS SOMBORNE WWTW | Due 2026-27 | Test - conf Anton to conf Dun |
| 08SO102420 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring Millbrook WTW | Due 2026-27 | Tanner's Brook |
| 08SO104732 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring Overton WWTW | Due 2026-27 | Test (Upper) |
| 08SO102833 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor OVERTON WWTW | Due 2026-27 | Test (Upper) |
| 08SO102577 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring REDLYNCH WTW | Due 2026-27 | REDLYNCH |
| 08SO102855 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor REDLYNCH WWTW | Due 2026-27 | Blackwater |
| 08SO102422 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring Romsey WTW | Due 2026-27 | Test - conf Dun to Tadburn Lake |
| 08SO102860 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor ROMSEY WWTW | Due 2026-27 | Test - conf Dun to Tadburn Lake |
| 08SO102503 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring Stockbridge WTW | Due 2026-27 | STOCKBRIDGE |
| 08SO102891 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor STOCKBRIDGE WWTW | Due 2026-27 | Test - conf Anton to conf Dun |
| 08SO102504 · a | U_MON4 | Monitoring | U_MON4b - Move AMP7 U_INV2 driver output to 2-minute flow monitoring West Wellow WTW | Due 2026-27 | Blackwater (Test and Itchen) |
| 08SO102922 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor WEST WELLOW WWTW | Due 2026-27 | Blackwater (Test and Itchen) |
| 08SO102506 · a | U_MON4 | Monitoring | U_MON4c - PR24 U_MON4 from U_INV2 investigation including civils Whiteparish WTW | Due 2026-27 | WHITEPARISH |
| 08SO102927 · a | U_MON3 | Monitoring | U_MON3a: MCERTS certification of an AMP7 U_MON3 driver output overflow operation monitor WHITEPARISH WWTW | Due 2026-27 | Whiteparish Trib |
| 08SO104950 · n | EnvAct_INV4 | Investigation | Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact KINGS SOMBORNE SSO | Due 2027-28 | Test - conf Anton to conf Dun |
| 08SO104950 · j | EnvAct_INV4 | Investigation | Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact REDLYNCH SSO | Due 2027-28 | Blackwater |
| 08SO104950 · os | EnvAct_INV4 | Investigation | Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact STOCKBRIDGE SSO | Due 2027-28 | Test - conf Anton to conf Dun |
| 08SO104950 · or | EnvAct_INV4 | Investigation | Investigation to determine the target number of spills from the storm overflow to protect the environment and demonstrate no local adverse ecological impact WEST WELLOW SSO | Due 2027-28 | Blackwater (Test and Itchen) |
| 08SO104002 · a | HD_IMP_NN | Improvement | Amend permit limit of Total N to 13.79 mg/l Barton Stacey WwTW | Due 2029-30 | Dever |
| 08SO103973 · a | HD_IMP_NN | Improvement | Amend permit limit of Total N to 37.90 mg/l EAST GRIMSTEAD | Due 2029-30 | Dun |
| 08SO104008 · a | HD_IMP_NN | Improvement | Amend permit limit of Total N to 10 mg/l Fullerton WwTW | Due 2029-30 | Test - conf Dever to conf Anton |
| 08SO103979 · a | HD_IMP_NN | Improvement | Amend permit limit of Total N to 10 mg/l KINGS SOMBORNE WWTW | Due 2029-30 | Test - conf Anton to conf Dun |
| 08SO100029 · a | NERC_IMP | Improvement | This project takes the outcomes of the strategy development (late AMP7/early AMP8) project and implements enhancement actions in collaboration with existing catchment partners. This project is looking to identify a plan for enhancements over the next 10 years to improve the River Anton, from both a quality and quantity perspective. River Anton - Working with Catchment Partners to develop a strategy and implement restoration of the River as part of the CABA chalk stream restoration flagship programme. | Due 2029-30 | Anton - Upper |
| 08SO104007 · a | HD_IMP_NN | Improvement | N reduction Romsey WwTW | Due 2029-30 | Test - conf Dun to Tadburn Lake |
| 08SO104009 · a | HD_IMP_NN | Improvement | Amend permit limit of Total N to 19.40 mg/l West Wellow WwTW | Due 2029-30 | Blackwater (Test and Itchen) |
| 08SO103965 · a | EnvAct_IMP2 | Improvement | Wetland + Lining KINGS SOMBORNE SSO | Due 2034-35 | Test - conf Anton to conf Dun |
| 08SO103955 · a | EnvAct_IMP2 | Improvement | Wetland + Lining REDLYNCH SSO | Due 2034-35 | Blackwater |
| 08SO103953 · a | EnvAct_IMP2 | Improvement | SuDS + Storage STOCKBRIDGE SSO | Due 2034-35 | Test - conf Anton to conf Dun |
| 08SO103900 · a | EnvAct_IMP2 | Improvement | SuDS + Storage WEST WELLOW SSO | Due 2034-35 | Blackwater (Test and Itchen) |
37 of 37 measures shown. A measure whose completion date has passed is shown as Complete; the water company's actual delivery against it is reported to the regulator but not published here.
There is no public change log
The live WINEP spreadsheet is internal, and there is no versioned public comparison or published reasons when a measure is re-dated or dropped. The only way to hold slippage to account is to archive every annual release and diff it yourself.
The 2027 pressure point
Most investigations must complete by 30 April 2027 to feed the 2030–35 programme. That date — not 2030 — is the one to hold: an investigation that slips past it cannot shape the next round of funded schemes.